62 Appendices
Pin List by Function
M400 Pin Sea-Doo Pin Function
Power
VBAT A26 B-M4, S06, L05
12 V Switched (System Relay)
Lambda Heater Supply
GND A10 B-F2, B-L1, B-
M2, C05
ECU Earth
, IGN4 Earth
GND A11 B-M3, R85,R87 ECU Earth
, Fuel Pump Relay Earth
8V ENG A12 not used
Optional: 8 V to SKM Module
5V ENG A02 A-K4, A-B4, B-
J3, B-K1
5 V Sensor Supply
Optional: GPS Power
0V ENG B16 B-K3, B-H3, B-
B3, A-A2, A-C4,
A-D4, A-H2, A-
J2, A-K2, A-J3,
A-J4
0 V Sensor Supply
8V AUX A13 E03 8
V to CAN Connector
5V AUX A09 A-F4 5 V Sensor Supply
0V AUX B15 L01
Lambda Sensor Ground
0V
COMM
B14 A-G2, E01,S01
0 V for CAN and STC devices
Outputs
Inj1 A19 A-B3 Injector Cylinder 1
Inj2 A20 A-K1 Injector Cylinder 2
Inj3 A21 A-J1 Injector Cylinder 3
Inj4 A22 not used
Inj5 A27 not used
Not Available in M400
Inj6 A28 not used Not Available in
M400
Inj7 A29 not used
Not Available in M400, M600
Inj8 A30 not used
Not Available in M400,
Optional: Available for Knock Module
SKM -
Knock Window
MoTeC
12 V Switched (System Relay)
Lambda Heater Supply
, IGN4 Earth
, Fuel Pump Relay Earth
Optional: 8 V to SKM Module
V to CAN Connector
Lambda Sensor Ground
0 V for CAN and STC devices
Not Available in M400
M400
Not Available in M400, M600
Not Available in M400,
M600.
Optional: Available for Knock Module
Knock Window