Motec ACL VIM Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Motec ACL VIM. MoTeC ACL VIM User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 99
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
MoTeC Central Logging System User Manual
Contents
Introduction ........................................................................ 1
Overview ............................................................................. 2
System Overview ................................................................................................ 2
ACL Advanced Central Logger ........................................................................... 2
Connected Devices ............................................................................................. 4
VIM Versatile Input Module...................................................................... 4
Display Devices ....................................................................................... 4
BR2 Beacon Receiver ............................................................................. 5
SLM Shift Light Module ........................................................................... 5
E888 / E816 Expanders ........................................................................... 5
GPS Global Positioning System .............................................................. 6
PLM Lambda Meter ................................................................................. 6
Telemetry Radio System ......................................................................... 6
ECU Engine Management Systems ........................................................ 7
Operation ............................................................................ 9
PC Communications ........................................................................................... 9
Software .............................................................................................................. 9
ACL Manager .......................................................................................... 9
i2 Pro Data Analysis .............................................................................. 10
Telemetry Monitor .................................................................................. 10
Display .............................................................................................................. 10
Display Elements ................................................................................... 11
Display Modes ....................................................................................... 13
Display Formatting ................................................................................. 15
Alarms............................................................................................................... 15
Data Logging .................................................................................................... 16
Overview................................................................................................ 16
Retrieving the Logged Data ................................................................... 19
Track Map Sensor Requirements .......................................................... 19
Functions & Calculations .................................................................................. 20
Measurement Inputs ......................................................................................... 21
Sensors ................................................................................................. 21
Input Basics ........................................................................................... 22
Input Types ............................................................................................ 23
Auxiliary Outputs ............................................................................................... 27
Communication Ports ....................................................................................... 27
Installation & Configuration ............................................ 29
Wiring................................................................................................................ 29
ACL Central Logger .......................................................................................... 30
Connected Devices ........................................................................................... 32
Przeglądanie stron 0
1 2 3 4 5 6 ... 98 99

Podsumowanie treści

Strona 1 - Contents

MoTeC Central Logging System User Manual Contents Introduction ... 1Overview

Strona 2

6 Overview The E888 / E816 connect to the ACL via CAN. The E888 has 8 x 10 bit thermocouple inputs, 8 x 10 bit voltage inputs, 4 digital inputs, 2 sw

Strona 3

MoTeC Overview 7 2. End of lap data which shows summary information at the end of a lap such as lap time, maximum temperatures etc. 3. Telemetry

Strona 5 - Introduction

MoTeC Operation 9 Operation PC Communications The ACL includes an Ethernet port which is used for communications with a PC. Most modern PCs have a

Strona 6 - Overview

10 Operation Communications Cable ACL Manager communicates with the ACL via an Ethernet cable. Refer to the PC Communications section for setup detai

Strona 7 - More Information

MoTeC Operation 11 Display Elements The display contains a Bar Graph, three Numeric Displays, a Centre Numeric Display and a Bottom Alpha / Numeri

Strona 8

12 Operation Numeric Displays The three Numeric Displays (Left, Right and Top Right) can be programmed to display any value, which may be different

Strona 9

MoTeC Operation 13 The Centre Numeric display is incorporated to show the current gear but may be used for other purposes. Bottom Alpha / Numeric

Strona 10 - Telemetry Radio System

14 Operation The Race Display is normally used to display minimal information, e.g. RPM, Lap Time, Fuel Remaining or Laps Remaining. The bottom displ

Strona 11 - MoTeC Overview 7

MoTeC Operation 15 Display Formatting Units The display units can be changed to suit the driver, for example the driver may prefer to see the engi

Strona 12

VIM Input Module ... 32ADL2 & SDL Display ...

Strona 13 - Operation

16 Operation speed has been above 50 km/h for 30 seconds. The speed comparison avoids the alarm showing during a pit stop due to heat soak. Additiona

Strona 14 - Display

MoTeC Operation 17 Start and Stop Logging Conditions To avoid logging data unnecessarily, logging can be started and stopped by user definable con

Strona 15 - Display Elements

18 Operation Update Rate Each input is measured at a maximum rate which is dependent on the capabilities of the measuring device and may also vary be

Strona 16 - Numeric Displays

MoTeC Operation 19 Real Time Value (For devices other than VIM, ADL2, SDL) The real time value from other devices and from internal calculations i

Strona 17 - Display Modes

20 Operation A Longitudinal G force sensor should be used if the vehicle has only one wheel speed sensor. This allows the analysis software to elimin

Strona 18 - Warm-up Mode

MoTeC Operation 21 General Purpose Calculations: The ACL also provides a number of general purpose calculations including: • 2D and 3D Lookup Tab

Strona 19 - Display Formatting

22 Operation To connect a thermocouple to an ADL2 a MoTeC thermocouple amplifier may be used. The amplifier measures the very weak signal from the th

Strona 20 - Data Logging

MoTeC Operation 23 Caution Operation outside the specified voltage range may cause damage to the device. The various measurement devices will spec

Strona 21 - Logging Rate

24 Operation Analogue voltage inputs are normally used to measure the signals from sensors with variable voltage outputs, such as potentiometers, 3-w

Strona 22

MoTeC Operation 25 Thermocouple Inputs Available on: E888 Thermocouple inputs are specifically designed for measuring K type thermocouples. Note

Strona 23 - Retrieving the Logged Data

MoTeC Central Logging System User Manual Appendix M: Connector Details ... 82A

Strona 24 - Functions & Calculations

26 Operation Switch Inputs Available on: ADL2, SDL, E888, E816 Switch inputs are generally used for the external toggle switches or press buttons. Sw

Strona 25 - Measurement Inputs

MoTeC Operation 27 Internal Sensors The various measurement devices may also contain internal sensors. For example, most devices measure battery v

Strona 26 - Input Basics

28 Operation allows all connected devices to communicate with each other. The CAN bus also has the advantage of being able to communicate at high spe

Strona 27 - Input Types

MoTeC Installation & Configuration 29 Installation & Configuration Wiring Wire MoTeC recommends the use of Tefzel insulated wire. For gene

Strona 28 - 24 Operation

30 Installation & Configuration ACL Central Logger ACL Mounting Dimensions Refer to Appendix Q: ACL Case Dimensions. Attachment Attach at the fo

Strona 29 - MoTeC Operation 25

MoTeC Installation & Configuration 31 Power Wiring The ACL uses a file system to store the logged data and needs to be shut down correctly to

Strona 30 - 26 Operation

32 Installation & Configuration Connected Devices VIM Input Module VIM Mounting Refer to Appendix R: VIM Case Dimensions. Attachment Attach at t

Strona 31 - Communication Ports

MoTeC Installation & Configuration 33 The other inputs can be used for potentiometers, voltage output devices and 2-wire variable resistance s

Strona 32 - Serial Communications Ports

34 Installation & Configuration ADL2 & SDL Display ADL2 & SDL Wiring The display device must be wired to the ACL via one of the ACL&apos

Strona 33

MoTeC Installation & Configuration 35 ADL2 & SDL Firmware ACL Manager will automatically update the firmware version in the device if nece

Strona 35 - ACL Firmware

36 Installation & Configuration Refer to the BR2 user manual for further details. BR2 Setup The BR2 beacon receiver has its own configuration pr

Strona 36 - Connected Devices

MoTeC Installation & Configuration 37 ACL Setup Outputs Setup Using ACL Manager, select Functions | Shift Light Module to configure the SLM.

Strona 37 - VIM Firmware

38 Installation & Configuration If not using CAN bus 0, click on the Advanced button to select the correct CAN bus. If a second expander is conn

Strona 38 - ADL2 & SDL Display

MoTeC Installation & Configuration 39 PLM Lambda Meter One or more PLMs can be connected to the ACL via CAN. For installations with multiple P

Strona 39 - BR2 Beacon Receiver

40 Installation & Configuration ECU Engine Management Systems An ECU may be connected to the ACL which will make some of the information in the

Strona 40 - SLM Shift Light Module

MoTeC Installation & Configuration 41 Refer to Appendix K: CAN Bus Wiring for details. ECU Setup Use the separate ECU manager software to setu

Strona 42 - MoTeC GPS

MoTeC ACL Manager Software 43 ACL Manager Software Introduction The following is an overview of the main concepts of the ACL Manager software. Mo

Strona 43

44 ACL Manager Software If the new wondow does not appear, click on the Windows Start button and select Run. Type ‘D:\moteccd’ Click on the button m

Strona 44 - ECU Connection via CAN

MoTeC ACL Manager Software 45 Toolbar The Tool Bar provides an alternative way of activating some of the commonly used items on the main menu.

Strona 45 - ECU Setup

MoTeC Introduction 1 Introduction Thank you for purchasing a MoTeC Central Logging System. This Manual Covers: • Overview, Operation, Installatio

Strona 46

46 ACL Manager Software Configuration Files The ACL configurations are stored in files on the PC hard disk and can be sent to the ACL at any time. W

Strona 47 - ACL Manager Software

MoTeC ACL Manager Software 47 Backups Whenever a file is saved, the previous contents of the file are saved in the ‘Save Backups’ directory. The

Strona 48 - Main Menu

48 ACL Manager Software Configuration Versions and Updating Updating The firmware inside the ACL can be updated by the user at any time to take adv

Strona 49 - Configuration

MoTeC ACL Manager Software 49 Converting Older Version Configuration Files An older version configuration file can be converted to the latest ver

Strona 50 - Configuration Files

50 ACL Manager Software Channels Channels are used to convey information between the various systems of the ACL. For example an input pin may feed a

Strona 51 - Changing the Configuration

MoTeC ACL Manager Software 51 Channel List MoTeC has defined an extensive list of channels. All systems within the ACL that generate values must

Strona 52 - Configuration File Version

52 ACL Manager Software Predefining these properties makes the channels easy to use throughout the rest of the software. Knowing the measurement typ

Strona 53

MoTeC ACL Manager Software 53 To expand a category click on the plus sign (+) next to the category name.

Strona 54 - Channels

54 ACL Manager Software Search Method This method lists all channels in alphabetical order and allows a channel to be found either by typing the fir

Strona 55 - Channel Properties

MoTeC ACL Manager Software 55 engine speeds but set at a lower engine oil pressure, which would cover the range from 500 to 1500 RPM, which might

Strona 56 - Selecting Channels

2 Overview Overview System Overview The ACL (Advanced Central Logger) forms the heart of a sophisticated and highly configurable data acquisition sys

Strona 57

56 ACL Manager Software Tests A number of tests are provided to check the operation of the ACL, such as the Inputs Test. To run one of the tests se

Strona 58 - Conditions Overview

MoTeC Windows Keyboard Use 57 Windows Keyboard Use This section gives some details on how to use the keyboard with Windows applications. Main Menu

Strona 59 - Checking Operation

58 Windows Keyboard Use Selecting an Item in a Window To access the various items in a window, press ALT + the key for the underlined letter of the

Strona 60 - Details Editor

MoTeC Windows Keyboard Use 59 Check Box A check box is used to tick on or off a particular option. Press ALT + the key for the underlined letter

Strona 61 - Windows Keyboard Use

60 Windows Keyboard Use Drop down List A drop down list is used to select from a number of items, but only the selected item is shown until a new it

Strona 62 - Using the Selected Item

MoTeC Windows Keyboard Use 61 The RIGHT ARROW key expands; expandable branches indicated by a plus sign (+) The LEFT ARROW key collapses; collapsi

Strona 63 - Radio Buttons

62 Appendices Appendices Appendix A: ACL General Specifications Physical Case Size 151(w) x 134(h) x 28(d) mm (excluding connector) Weight 460 gram

Strona 64 - 60 Windows Keyboard Use

MoTeC Appendices 63 Appendix B: ACL Options Summary The following options are available when the devices are used as part of the Central Logging

Strona 65

64 Appendices Appendix C: VIM General Specifications Physical Case Size 38(w) x 90(h) x 26.2(d) mm (excluding connector) Weight 120 grams (0.85 lb)

Strona 66 - Appendices

MoTeC Appendices 65 Appendix D: VIM Input Specifications Analogue Inputs VIM Analogue Input Specifications Input Type Qty Update Rate (Hz) ++ An

Strona 67 - Remote Logging Option

MoTeC Overview 3 and perform functions such as Warning Alarms, Fuel Prediction, Engine Logs, Lookup Tables and many more. The ACL includes 1 gigab

Strona 68

66 Appendices ** Inputs are sampled at 40 kHz, 8 samples are averaged to give a 5 kHz update rate. *** This specification only applies if the gains o

Strona 69 - Analogue Inputs

MoTeC Appendices 67 AV H4 300 500 AV H5 550 500 AV H6 800 500 AV H7 1050 500 AV H8 1300 500 AV S1 150 2000 AV S2 400 2000 AV D1 5

Strona 70 - VIM Pull-up Resistor Pins

68 Appendices Appendix E: Update Rate Summary The following table shows the maximum update rates for the various measurement devices Device Input T

Strona 71 - VIM Speed Inputs

MoTeC Appendices 69 Appendix F: CAN Bus Bandwidth Limit The total available CAN bandwidth available on a single CAN bus is 1 Mbit/sec. The band

Strona 72 - 68 Appendices

70 Appendices Other Devices BR2 Negligible SLM Negligible PLM Negligible SDL TBD ADL2 TBD MDD TBD M800 ECU TBD

Strona 73 - E888/E816

MoTeC Appendices 71 Appendix G: ACL Manager Command Line Usage: aclmanager.exe -c[connection name] -x -l -e –t -p -s –u [config file name] [co

Strona 74 - Other Devices

72 Appendices -t (Optional) Perform a “Get Tell-tale Values” operation. -p (Optional) Perform a “Print Summary” operation. Note The config file must

Strona 75 - Options:

MoTeC Appendices 73 Appendix H: Comms Error Codes The "Comms CAN x Diagnostic" and "Comms RS232 Diagnostic" channels seen ca

Strona 76 - 72 Appendices

74 Appendices length. 8 OVERRUN Receive or transmit overrun error. In the receive case a byte was received before the previous byte was read indica

Strona 77 - General CAN Errors

MoTeC Appendices 75 ACL Errors These errors are generated by the ACL communications system. 2 FRAMING Incorrect number of samples received. 25

Strona 78 - "VIMCOM" Errors

4 Overview Connected Devices The following topics describe the basic functions of the main devices that can be connected to the ACL. VIM Versatile I

Strona 79 - MoTeC Appendices 75

76 Appendices 4102 SYNC EXCEEDED Data not sent due to excessive sync error (synchronisation too far out)

Strona 80 - 76 Appendices

MoTeC Appendices 77 Appendix I: Ethernet Communications Cable The ACL communicates with a PC via a CAT5 Ethernet cable that is terminated with a

Strona 81 - MoTeC Appendices 77

78 Appendices Appendix J: ECU to ACL Wiring (RS232) The following details the methods for connecting the various MoTeC ECUs to the ACL via RS232. In

Strona 82 - M800 / M880

MoTeC Appendices 79 M48, M4 (pre M4e) and M8 The M48 & M8 and M4 (pre M4e) require the use of a CIM module or a PCI Cable to convert the log

Strona 83 - M48, M4 (pre M4e) and M8

80 Appendices Appendix K: CAN Bus Wiring The CAN bus should consist of a twisted pair trunk with 100R (0.25 watt) terminating resistors at each end o

Strona 84 - Appendix K: CAN Bus Wiring

MoTeC Appendices 81 Appendix L: Wire Information M22759/16 Wire Ratings (For Various Wire Gauges) Insulation Material : Tefzel Conductor : Tin P

Strona 85 - Appendix L: Wire Information

82 Appendices Appendix M: Connector Details ACL Mating Connectors 22 Pin Connector: Deutsch AS612-35SN 5 Pin Connector: Deutsch ASL606-05SN-HE VIM Ma

Strona 86 - For 5 Pin

MoTeC Appendices 83 For 22 Pin Straight Raychem 202K142, Hellerman 154-42-G Right Angle Raychem 222K142, Hellerman 1154-42-G For 55 Pin Str

Strona 87 - MoTeC Appendices 83

84 Appendices Appendix N: VIM Pin List by Function VIM 5 Pin Connector Pin Name Function Power 1 BAT – Battery – 3 BAT + Battery + CAN Bus 4 CAN

Strona 88 - VIM 55 Pin Connector

MoTeC Appendices 85 Differential Analogue Volt Inputs 15 AV D1+ Analogue Voltage Differential 1+ 16 AV D1– Analogue Voltage Differential 1–

Strona 89 - MoTeC Appendices 85

MoTeC Overview 5 The input and output pins on the display devices are fully accessible (dependant on the I/O options enabled), with exception of a

Strona 90 - 86 Appendices

86 Appendices 32 0V 2 Sensor 0 V 2 40 0V 2 Sensor 0 V 2 17 0V 3 Sensor 0 V 3 25 0V 3 Sensor 0 V 3 4 0V 4 Sensor 0 V 4 10 0V 4 Sensor 0 V

Strona 91 - MoTeC Appendices 87

MoTeC Appendices 87 Appendix O: VIM Pin List by Pin Number VIM 5 Pin Connector Pin Name Function 1 BAT – Battery – 2 Not Used 3 BAT + Battery

Strona 92 - 88 Appendices

88 Appendices 25 0V 3 Sensor 0 V 3 26 5V Sensor 5 V 27 5V Sensor 5 V 28 AV D7+ Analogue Voltage Differential 7 + 29 AV D7– Analogue Voltage D

Strona 93 - ACL 22 Pin Connector

MoTeC Appendices 89 Appendix P: ACL Pin List by Pin Number ACL 5 Pin Connector Pin Name Function 1 RX+ Ethernet Receive + (Orange/White) 2 R

Strona 94 - 90 Appendices

90 Appendices Appendix Q: ACL Case Dimensions

Strona 95 - MoTeC Appendices 91

MoTeC Appendices 91 Appendix R: VIM Case Dimensions

Komentarze do niniejszej Instrukcji

Brak uwag